< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=1003690837628708&ev=PageView&noscript=1" /> China Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart factory and manufacturers | Wonsmart
1

product

Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart


Product Detail

Product Tags

Related Video

Feedback (2)

With advanced technologies and facilities, strict quality control, reasonable price, superior service and close co-operation with customers, we are devoted to providing the best value for our customers for High Pressure Low Noisy Air Blower , Large Air Blower , Electric Hot Air Blower , Welcome all nice buyers communicate details of products and ideas with us!!
Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart Detail:

Blower Features

Brand name: Wonsmart

High pressure with dc brushless motor

Blower type: Centrifugal fan

Voltage:24vdc

Bearing: NMB ball bearing

Type: Centrifugal Fan

Applicable Industries:Manufacturing Plant

Electric Current Type: DC

Blade Material: plastic

Mounting: Ceiling Fan

Place of Origin:Zhejiang, China

Voltage:24VDC

Certification: ce, RoHS, ETL

Warranty: 1 Year

After-sales Service Provided: Online support

Life time(MTTF): >20,000hours (under 25 degree C)

Weight: 400 grams

Housing material:PC

Unit size: 90*90*50mm

Motor type:Three Phase DC Brushless Motor

Controller: external

Static pressure: 8kPa

1 (1)
1 (2)

Drawing

Blower Performance

WS9250-24-240-X200 blower can reach maximum 44m3/h airflow at 0 kpa pressure and maximum 8kpa static pressure.It has maximum output air power when this blower run at 4.5kPa resistance if we set 100% PWM, It has maximum efficiency when this blower run at 5.5kPa resistance if we set 100% PWM.Other load point performance refer to below P-Q curve:

WS9250-24-240-X200-Model_00

DC Brushless Blower Advantage

(1) WS9250-24-240-X200 blower is with brushless motors and NMB ball bearings inside which indicates very long life time; MTTF of this blower can reach more than 15,000hours at 20 degree C environmental temperature

(2) This blower needs no maintence

(3) This blower drived by a brushless motor controller have many different control functions such as speed regulation,speed pulse output,fast acceleration, brake etc.it can be controlled by intelligent machine and equipment easily

(4) Drived by brushless motor driver the blower will have over current, under/over voltage,stall protections.

Applications

This blower can be widely used onto air pollution detector,air bed,air cushion machine and ventilators.

How to Use the Blower Correctly

This blower can run at CCW direction only.Reverse the impeller running direction can not change the air direction.

Filter onto the inlet to protect the blower from dust and water.

Keep the environmental temperature as low as possible to make the blower life time longer.

FAQ

Q: What is the MTTF of this centrifugal air blower?

A: MTTF of this centrifugal air blower is 20,000+ hours under 25 C degree.

Q: Can we use this centrifugal air blower to suct water?

A:This blower fan can not be used to suck water. If you need to suck water, you can ask us to choose proper item for this special working condition.

Q: Can we use this centrifugal air blower to suck dust directly?

A: This blower fan can not be used to suck dust directly.If you need to suck dust, you can ask us to choose proper item for this special working condition.

The speed of a DC motor can be increased by field weakening. Reducing the field strength is done by inserting resistance in series with a shunt field, or inserting resistances around a series-connected field winding, to reduce current in the field winding. When the field is weakened, the back-emf reduces, so a larger current flows through the armature winding and this increases the speed. Field weakening is not used on its own but in combination with other methods, such as series-parallel control.

The speed of a DC motor can be increased by field weakening. Reducing the field strength is done by inserting resistance in series with a shunt field, or inserting resistances around a series-connected field winding, to reduce current in the field winding. When the field is weakened, the back-emf reduces, so a larger current flows through the armature winding and this increases the speed. Field weakening is not used on its own but in combination with other methods, such as series-parallel control.


Product detail pictures:

Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart detail pictures

Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart detail pictures


Related Product Guide:

Fast and great quotations, informed advisers to help you choose the correct solution that suits all your requirements, a short creation time, responsible top quality manage and distinct providers for paying and shipping affairs for Professional China 12v Dc Centrifugal Blower - small air centrifugal side channel blower – Wonsmart , The product will supply to all over the world, such as: Porto, Czech republic, Sheffield, With the goal of "zero defect". To care for the environment, and social returns, care employee social responsibility as own duty. We welcome friends from all over the world to visit and guide us so that we can achieve the win-win goal together.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Mary from America - 2018.12.11 14:13
    Good quality and fast delivery, it's very nice. Some products have a little bit problem, but the supplier replaced timely, overall, we are satisfied.
    5 Stars By trameka milhouse from Surabaya - 2017.07.07 13:00
    Write your message here and send it to us