< img height="1" width="1" style="display:none" src="https://www.facebook.com/tr?id=1003690837628708&ev=PageView&noscript=1" /> China Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart factory and manufacturers | Wonsmart
1

product

Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart


Product Detail

Product Tags

Related Video

Feedback (2)

We depend on sturdy technical force and continually create sophisticated technologies to meet the demand of Centrifugal Fan Manufacturers , Inflatable Slide Blower , Industrial Hot Air Blower Machine , All the opinions and suggestions will be greatly appreciated! The good cooperation could improve both of us into better development!
Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart Detail:

Blower Features

Brand name: Wonsmart

High pressure with dc brushless motor

Blower type: Centrifugal fan

Voltage: 12 vdc

Bearing: NMB ball bearing

Type: Centrifugal Fan

Applicable Industries:Manufacturing Plant

Electric Current Type: DC

Blade Material: plastic

Mounting: Ceiling Fan

Place of Origin:Zhejiang, China

Certification: ce, RoHS,

Warranty: 1 Year

After-sales Service Provided: Online support

Life time(MTTF): >20,000 hours (under 25 degree C)

Weight: 63 grams

Housing material:PC

Controller: internal

Static pressure: 4.8kPa

1 (1)
1 (2)

Drawing

Blower Performance

Low noise CPAP Blower can reach maximum 8m3/h airflow at 0 kpa pressure and maximum 4.8 kpa static pressure.It has maximum output air power when this blower run at 3kPa resistance if we set 100% PWM, It has maximum efficiency when this blower run at 3.5kPa resistance if we set 100% PWM. Other load point performance refer to below P-Q curve:

1

DC Brushless Blower Advantage

(1).Low noise CPAP blower is with brushless motors and NMB ball bearings inside which indicates very long life time

(2).MTTF of this blower can reach more than 20,000 hours at 20 degree C environmental temperature.

(3).This blower drived by a brushless motor controller have many different control functions such as speed regulation,speed pulse output,fast acceleration, brake etc.

(4).It can be controlled by intelligent machine and equipment easily.

Drived by brushless motor driver the blower will have over current, under/over voltage,stall protections.

How to Use the Blower Correctly

This blower can run at CCW direction only.Reverse the impeller running direction can not change the air direction.

Filter onto the inlet to protect the blower from dust and water.

Keep the environmental temperature as low as possible to make the blower lifetime longer.

This is internal drive and speed controllable version blower, external driver board is not required.

FAQ

Q: Can you design a new blower fan if we give you target performance?

A: Yes, we offer ODM service for both blower fan and controller board.

Q: What can do if the working condition is dirty?

A: A filter is strongly recommended to assemble onto the the inlet of the blower fan

Q: How to decrease the noise of the blower?

A: Many of our customers use foam, silicone to fill between blower fan and machine to insulate the blower noise.

Centrifugal pumps are used to transport fluids by the conversion of rotational kinetic energy to the hydrodynamic energy of the fluid flow. The rotational energy typically comes from an engine or electric motor. They are a sub-class of dynamic axisymmetric work-absorbing turbomachinery. The fluid enters the pump impeller along or near to the rotating axis and is accelerated by the impeller, flowing radially outward into a diffuser or volute chamber (casing), from which it exits.

Common uses include water, sewage, agriculture, petroleum and petrochemical pumping. Centrifugal pumps are often chosen for their high flow rate capabilities, abrasive solution compatibility, mixing potential, as well as their relatively simple engineering. A centrifugal fan is commonly used to implement an air handling unit or vacuum cleaner. The reverse function of the centrifugal pump is a water turbine converting potential energy of water pressure into mechanical rotational energy.


Product detail pictures:

Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart detail pictures

Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart detail pictures


Related Product Guide:

We enjoy a very good reputation among our customers for our excellent product quality, competitive price and the best service for Special Design for Ventilator Centrifugal Blower Fan Dc 24v - Low noise CPAP Blower – Wonsmart , The product will supply to all over the world, such as: Greece, Jakarta, Rwanda, As a way to use the resource on the expanding info in international trade, we welcome prospects from everywhere on the web and offline. In spite on the high quality objects we offer you, effective and satisfying consultation service is supplied by our qualified after-sale service group. Item lists and in depth parameters and any other info weil be sent to you timely for the inquiries. So you should make contact with us by sending us emails or call us when you've got any questions about our organization. ou could also get our address information from our site and come to our enterprise. We get a field survey of our merchandise. We're confident that we are going to share mutual accomplishment and create solid co-operation relations with our companions within this market place. We're seeking forward for your inquiries.
  • We have been appreciated the Chinese manufacturing, this time also did not let us disappoint,good job!
    5 Stars By Miguel from Jakarta - 2017.01.28 19:59
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Eudora from Korea - 2017.11.29 11:09
    Write your message here and send it to us